AFTER “IMPORTANT” IN BOLD TYPE ON
PAGE ONE. Reattach dome cover back
onto packing nut.
6. ALLOW VALVE TO RUN IN WARM POSI-
TION FOR A FEW MINUTES TO TOTALLY
FLUSH SYSTEM. IF SYSTEM IS QUITE
DIRTY, REMOVE VALVE SPINDLE OR STOP
SPINDLES (IF SO EQUIPPED) TO INSURE
PROPER FLUSHING. See service instruc-
tions.
7. Assemble diverter (T-139) and escutch-
eon (T-131) by installing diverter into “U”
notch located on escutcheon. Diverter
will be retained in “U” notch by integral
tabs (Models A and B only).
8. Install escutcheon on valve making sure
diverter/volume shaft (A) aligns with
mating key slot in top of diverter/volume
spindle (B) (Models A and B only).
A. B.
Push assembled escutcheon against wall
and secure to valve with two escutcheon
screws (T3-28). Snap Dial (T-130A, T-130B,
or T-132) into escutcheon slots provided.
Mount temperature control handle on
valve spindle spline as shown in figure 9.
Install shower arm, flange and shower
head. See Figures 2 and 3.
9. Do not install positive shut-off devices
on the outlet of this valve or devices that
do not allow the valve to flow at least 1
GPM at 50 psi inlet pressure. EXCEPTION:
If a self-closing or slow-closing valve is
installed on the outlet, the supplies of the
valve must be equipped with checks to
eliminate hot to cold by-pass in the event
the valve’s handle is not turned to off after
use. Contact your factory representative
or Symmons directly for information on
available checks.
FIBERGLASS WALL INSTALLATION
When installing Allura
®
in fiberglass or
panel walls and it is desired to sandwich
wall between valve body and escutch-
eon, cut hole in wall as shown in Figure
5 and mount valve with
T-177 wall mounting flange from rear.
Note: It is always recommended
to secure valve piping to rough
construction and not depend on
fiberglass wall for valve mounting
security. On panel walls over 1” thick,
install in conventional manner.
4 3/4"
120mm
approx.
24"
610mm
6 1/4''
158mm
FIGURE 3
Model B: Shower System
THICK WALL
HOLE SIZE
1
16
''
to
3
4
''
2mm 19mm
T-177 Wall Mounting Flange
For 21mm to 1" 25mm
thick wall order part no. T-193
13
16
''
4" (101mm) Max
3" (75mm) Min
FIGURE 5
Install plug here for
shower only installation
Install plug here for
tub only installation
Copper sweat plug
1/2"-14 NPT plug
(pipe sealer required)